OPTIBAR OP 5100

Orifice assembly with measuring flanges (ASME 16.36)

  • With RF sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 5100

OPTIBAR OP 5100

The OPTIBAR OP 5100 is an orifice plate assembly with measuring flanges (acc. to ASME 16.36), flange taps and RF (raised face) sealing face. The DP flow element stands for high safety in liquid, gas or steam applications.

The orifice assembly comes complete with all required installation hardware including the orifice plate, a pair of flanges with integrated taps, set of gaskets, bolts, nuts as well as jack screws to help with separating the flanges for orifice inspection. Depending on the customer requirements, the typical 12″ or 34″ taps have a BWE, thread or flange connection. Taps can be equipped with optional condensate chambers and shut-off valves.

Product highlights

  • Completely pre-assembled
  • Pressure values are averaged within integrated annular chambers resulting in increased accuracy
  • Sizing: EN ISO 5167, ASME MFC-3M, AGA 3, ASME PTC 19.5 2004, GOST 8.586, RD 50-411-83
  • Orifice plate is removable and easily replaced without replacing the carrier assembly
  • Lowest uncertainty of discharge coefficient
  • High Reynolds number permissible according to norm

Typical applications

  • For differential pressure flow measurement with OPTIBAR DP 7060 transmitter
  • Liquid, gas or steam applications with higher safety requirements

Related products

Compact orifice plate flowmeter

Integral DP flowmeter for liquids, gases and steam

  • Fast and easy installation without additional engineering, impulse lines and supports
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Line size: DN50…600 / 2…24"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

View product details

Integral orifice meter run assembly

DP flowmeter for process applications with small line sizes (down to DN15 / ½")

  • Standardised calibrated meter run assembly, designed acc. to ISO 5167 or ISO TR 15377
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Flange: DN15…100 / ½...4"
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA

View product details

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 400 bar / 5800 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

View product details