OPTISWITCH 5150
Vibration level switch for liquids in hygienic applications
- Point level detection of liquids in the food, beverage and pharmaceutical industry
- Polished tuning fork to meet hygienic requirements
- Density: ≥0.5 g/cm3 / 0.018 lb/in3
- -50…+250°C / -58…+482°F; -1…64 barg / -14.5…925 psig
OPTISWITCH 5150 C – Version with stainless steel housing and Tri-clamp connection
The OPTISWITCH 5150 is a vibration level switch with polished tuning fork for liquid hygienic applications. It is a universal and reliable device for level detection in vessels. It detects low or high level and is mostly used for overfill, dry-run or pump protection. Installations in pipelines are also possible.
Product highlights
- Polished tuning fork with a large choice of hygienic process fittings
- Optional adapter for high temperatures up to +250°C / +482°F
- Outputs: relay, transistor, 2-wire, NAMUR or contactless electronic switch
- Optional gas-tight lead-through for toxic gases
- In compliance with FDA and EC1935/2004
Typical applications
- Hygienic applications in the food, beverage and pharmaceutical industries
- Level detection, overfill protection, dry-run protection, pump protection
General information
Measurement principle | Vibrating |
Level measurement type | Point level detection |
Measured media | Liquids |
Contact to measured medium | Yes |
Interface measurement | No |
Probe length | 80…6000 mm/ 3…236 in |
Process pressure | -1…64 barg/ -14.5…925 psig |
Process temperature | -50…250°C/ -58…482°F |
Wetted parts | Austenitic stainless steel (1.4404/316L) |
Gaskets | Ethylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM/FPM), Kalrez® 6375, PFA |
Process connections
Thread connections | Male: G¾, G1 ¾ NPT, 1 NPT |
Hygienic connections | Dairy screw (DIN 11851): DN40 Tri-Clamp®: 1", 1 1/2", 2" Varivent®: N SMS (1145): 38 mm Fitting with compression nut: F40 (PN25) |
Communication
Discrete outputs | 2-wire (8/16 mA), Contactless, NAMUR, Relay, Transistor |
Approvals/Standards
Certificates/Approvals Hygienic | 3A, EC 1935/2004, FDA |
Related products
SU 502
Single channel controller for vibration level switches with 8/16 mA output
- Signal conditioner for simple control of point-level detection via integrated relay
- Optional 2nd relay: configurable as fail-safe relay or as second level detection relay
- Designed for installation on a DIN rail
- Approved for use in hazardous areas
Download Center
OPTISWITCH
Download Center
- Technical datasheets and handbooks
- Flyers and brochures
- Certificates and approvals
- Software and driver